A-A-50012
5. All machines shall be supplied with:
a. water inlet(s)
b. solenoid valve(s)
c. vacuum breaker
d. flow control(s)
e. silverware trap/splash guard
f. control panel
6. When specified, machines shall be supplied with an 18 inches or 15 inches diameter stainless steel cone or a 16 inches x 19 inches x 7 inches stainless steel sink.
7. Machines shall have adjustable legs or feet and when installed shall provide for a minimum of 3 inches between the underside of the unit and the floor to allow for proper cleaning.
8. In normal operation, the agitation shall be sufficient to flush the interior surfaces of the cone and reduction chamber, when the unit is supplied with water at the specified flow rate.
9. The control panel shall have automatic reversing to provide for alternate rotation each time the motor is started to minimize wear of cutting members. Control panels shall also be equipped with positive flush allowing the motor and water to run for a period of 2 to 4 minutes after the grinding operation is completed so that the machine and drain line are thoroughly flushed. The control panel shall be housed in a NEMA 12 inclosure.
10. Unless otherwise specified, machines shall be designed to operate on 208 V, 60Hz, 3 Ph power.
Certification
The contractor shall certify that the product offered meets the salient characteristics of this description, and that the product conforms to the producer’s own drawings, specifications, standards and quality assurance practices and is the same product sold in the commercial marketplace. The Government reserves the right to require proof of such conformance prior to first delivery and thereafter as may be otherwise provided for under the provisions of the contract.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744